Smart String Energy Storage System

Overview


Smart String Energy Storage System

  • Strong Expansibility: Support 16 modules in parallel.
  • Meticulous Care: Each module can be independentlymanaged and operated to ensurethe safety of the system.
  • Easy Management: Pulley bottom,manual switch,and visual supervision interface.
  • Stronger Compatibility: Cover allmainstream protocols andmatch most mainstream inverters, 1C discharge.
  • Long Life: 4 times long static and 8 consistencyscreening make the battery more durable.
  • Safety & reliability: Nano-coating and self-healing technologyconstruct the LPF channelto add a firewall to the battery.
  • Certifications +

    Customized service is welcome. Contact us

    FLCD16-10048

    Performance
    Battery Module Model
    Battery Module Specification51.2V 100AH (100A)
    Battery Module Energy5KWH
    Battery Module Maximum Output Power4.2KW
    Battery Module Peak Output Power5KW 10S
    Battery Module Rated Voltage(DC)51.2V
    Battery Module BMS A]lowable Load Current100A
    Battery Module DC Voltage Range44.8V~58.4V
    Inverter Operating Voltage Range (Single Phase)200V-240V
    Inverter Operating Voltage Range (Three Phase)340V-600V
    Communication
    DisplaySOC Status Indication, LED Indicator Screen
    ProtocolRS485 /RS232/ CAN (For parallel systems only)
    General Parameters
    Dimensions of Battery Module (Width x Height x Thickness)
    Weight (Including tools such as bracket tools)
    InstallationFloor (No more than 5 stacks per group)
    Working Temperature-20C~+55C
    Maximum Working Altitude4000 m(Derating above 2000 m)
    Installation EnvironmentOutdoor/ Indoor(*Please refer to the user manual for installation conditions)
    Working Relative Humidity5%~95%
    Cooling ModeNatural Convection
    Protection GradeIP 54
    CellLithium Iron Phosphate (LFP)
    ExpansibilityA maximum of 16 modules can be used in parallel
    Matching InverterMost current mainstream inverters (lithium)
    Satisfied criteria
    CertificatesCE,CEC,IEC62619,IEC 60730,UN38.3
    *1 Test conditions: Based on the manufacturing date, 0.2C charge and discharge rate at 100% depth of discharge (DOD) at 25°C.
    *2 The weight of the battery module is subject to the actual object, and a tolerance of +3% is allowed.
    *3 The installation of the battery pack is related to product quality assurance as well as safe and stable operation. Please follow therequirements of the user manual for standard installation, use and routine maintenance.