NSFL040J10 192V 40Ah Lithium ion Battery

Customized service is welcome. Contact us

Overview


  • Longer Cycle Life: Offers up to 15 times longer cycle life and 5 times longer float/calendar life than lead acid battery.
  • Lighter Weight: About 40% weight of a comparable lead acid battery, save up to 60% in weight.
  • Quick Charge: Short charge time compared with lead acid battery.
  • Low Self-Discharge: Lower self-discharge compared with lead acid battery, longer storage time without recharging.
  • Superior Safety: Multi-protection methods built inside to protect the battery from overcharge, over discharge and short circuit situation.
  • High Efficient: Higher round-trip energy efficiency of the average (92%) than lead acid battery 80% (discharge from 100% to 0% and back to 100% charged).
  • Certifications:
  • ISO-9001 ISO-14001 Iso_45001 CE_marking_logo UN38.3-icon CQC
    Compliant to: IEC 62133-2

    NSFL040J10 192V 40Ah Lithium ion Battery

    Download Datasheet

    Specifications

    Nominal voltage192V
    Nominal capacity40Ah
    DimensionsLength620±2mm (24.41inch)
    Width480±2mm (18.89inch)
    Height311±2mm (12.24inch)
    Total height311±2mm (12.24inch)
    Approx. weight80.5kg (177.47lbs)±2.5kg

    Characteristics

    Electrical
    Parameters
    (25°C)
    Rated Voltage192V
    Rated Capacity (C5)40Ah@25°C
    Energy7680Wh
    Months Self Discharge<3%
    Charge Efficiency99.5%@ 0.2C
    Discharge Efficiency96-99%@ 1C
    Terminal DiameterM8
    Internal resistance (Fully charged, 25°C)≤300mΩ
    Cycle life>3000 cycles @ 0.2C 100%D.O.D
    Capacity
    affected by
    temperature
    40°C101%
    25°C100%
    0°C90%
    -10°C75%
    Nominal operating temperature25°C± 3°C (77°F± 5°F)
    Operating
    temperature
    range
    Discharge– 20°C~ 60°C (-4°F ~ 140°F)
    Charge0°C~ 45°C (32°F ~ 113°F)
    Storage0°C~ 40°C (32°F ~ 104°F)
    Water Dust ResistanceIP50
    Charge Voltage216V
    Standard Charge Mode
    (25°C±2°C, <75%RH)
    0.2CA Constant Current to 216V,
    then Constant Voltage 216V
    until the current drops to 0.02CA,
    before use, rest 30 minutes
    Charge Current8.0A
    Maximum Charge Current20A
    Charge Cut off Voltage219V
    Continuous Discharge Current40A
    Maximum Pulse Current120A (<10ms)
    Discharge Cut Off Voltage180V
    Communicate Protocol (optional)RS485/RS232/CAN
    SOC (optional)LED/PC Software/Screen
    Application connection1 string 1 parallel
    MechanicalCells60 Strings
    ContainerMetal